FDJ 16-300mm² 1KV Low Voltage Distribution Line protection against reverse electricity and Full Insulation Protective Grounding Device

Short Description:

The anti-power-down protection device is suitable for low-voltage insulated distribution lines of 1KV and below on both sides of the tie switch, at the joints of branch poles and tension poles, and at the branch line points that may be reversed (or the branch line with a three-phase power meter installed) The grounding protection of the grounding point of the power failure should be set on the wire of the power failure.


Product Detail

Product Tags

Product Description

The anti-power-down protection device is suitable for low-voltage insulated distribution lines of 1KV and below on both sides of the tie switch, at the joints of branch poles and tension poles, and at the branch line points that may be reversed (or the branch line with a three-phase power meter installed) The grounding protection of the grounding point of the power failure should be set on the wire of the power failure.

electric power fittings protection againgst reverse electricity

Technical parameters and structure dimensions

参数

形象5

Product features and Installation matters

characteristic:
1. Keep the line in an insulated state and eliminate the hidden danger of electric shock
2. Easy to install, open the button to connect the ground wire directly
3. The combination of wire protection copper foil and insulating tape greatly enhances the anti-oxidation performance of the conductor and improves the life of the cable
4. Double protection, that is to prevent water vapor or air from entering the interface, and ensure the insulation effect when the interface is not in use
5. It can be reused and has the same life as the wire. It is an energy-saving and environmentally friendly product.
6. Stable product performance, maintenance-free, maintenance-free, greatly reducing maintenance costs
Install:
1. Strip the wire insulation about 70-75mm,
2. Wrap tinned copper foil to protect the cable conductors,
3. Wrap 5-8 layers of electrical tape around the ends of the two insulating layers,
4. Cut the length of the waterproof sealing tape according to the installed wire section, wrap both ends,
5. Install the anti-shock insulating protective cover, fasten the buckles one by one,
6. Product installation completion diagram,

Electric power fittings grounding device
electric power fittings grounding device

Product use environment

1. Altitude: ≤ 1000M
2. Ambient temperature: -25℃~+50℃
3. Sunlight intensity: up to 0.1W/cm2 (wind speed: 0.5m/s)
4. Maximum temperature difference: 25K
5. Maximum wind speed: 35m/s
6. Ice thickness: ≤ 10mm
7. Earthquake resistance: ≤ class 8
8. Installation location: outdoor

electric power fittings grounding device

Product details

electric power fittings protection against reverse electricity

Products real shot

electric power fittings grounding device

A corner of the production workshop

车间
electric power fittings copper wire clip

Product packaging

包装

Product application case

electric power fittings grounding device
应用