GCS 400V 600V 4000A Hot selling low voltage withdrawable enclosed switchgear

Short Description:

GCS low-voltage withdrawable switchgear (hereinafter referred to as “switch Equipment”) is designed and developed by our company according to the requirements of the design unit and power users in line with national conditions, has high technical performance indicators, can meet the needs of the development of the power market, and can compete with the introduction of existing low-voltage products.


Product Detail

Product Tags

Product Description

This product has been widely used by power users. The switch cabinet is suitable for distribution systems in power plants, petroleum, chemical, metallurgy, textile, high-rise buildings and other industries. In large power plants, petrochemical systems and other places with a high degree of automation and requiring computer interfaces, it is used as a Low-voltage complete power distribution device for power distribution, motor centralized control and reactive power compensation in power generation and power supply systems. Three-phase AC frequency 50 (60) Hz, rated working voltage 380V (400V), (660V), rated current 4000A and below.
This product complies with GB7251 low-voltage switchgear and control equipment, JB/T9661 low-voltage lead-out switchgear and IEC439 low-voltage switchgear and control equipment standards.

形象9

Model Description

型号含义
形象1

Product technical parameters and external dimensions

技术参数

安装示意图2

安装示意图3

安装示意图4

形象5

Product structure features

1.Increase the heat capacity of the adapter, and greatly reduce the additional temperature rise caused by the temperature rise of the adapter to the connector, cable head, and spacer plate.
2.The separation between functional units and compartments is clear and reliable, and the failure of one unit does not affect the work of other units, so that the failure is limited to a minimum.
3.The horizontal arrangement of the busbar makes the device have good dynamic and thermal stability, and can withstand the impact of 80/176kA short-circuit current.
4.The number of circuits in a single MCC cabinet is as many as 22, and the needs of large single-unit power generation, petrochemical systems and other industries for automated electric door (machine) groups are fully considered.
5.The connection between the device and the external cable is completed in the cable compartment, and the cables can be entered and exited up and down. The zero sequence current transformer is placed in the cable compartment, making installation and maintenance easy.
6.The drawer unit has a sufficient number of secondary plug-ins (32 pairs for 1 unit and above, 20 pairs for 1/2 unit). It can meet the requirements of the number of connection points of the computer interface and the automatic control loop.

形象2

Environment condition

1. Ambient air temperature: -5~+40 and the average temperature should not exceed +35 in 24h.
2. Install and use indoors. Altitude above sea level for operation site should not exceed 2000M.
3. Relative humidity should not exceed 50% at max temperature +40. Higher relative humidity is allowed at lower temperature. Ex. 90% at +20. But in view of the temperature change, it is possible that moderate dews will produce casually.
4. Installation gradient not exceed 5.
5. Install in the places without fierce vibration and shock and the sites insufficient to erode the electrical components.
6. Any specific requirement, consult with manufactory.

形象.

Product details

细节4
细节5

Products real shot

实拍1

A corner of the production workshop

车间..

Product packaging

包装

Product application case

案例.

  • Previous:
  • Next:

  • Write your message here and send it to us